Vermont Castings 360DVSR Operations Instructions Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10
Vermont Castings, Majestic Products, 360DVS Series
10002547
Alternative Switch Location
The remote switch can be installed on the front or the
side of the access door. Simply mount the switch to the
bracket provided and screw the bracket to either side
of the frame, lining up the screws with the prepunched
holes (Fig. 8).
Remote_Switch
TP
TH
TP
TH
Gas
Control
Valve
Remote ON/OFF switch
Fig. 7 Remote switch wiring diagram for R models
The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes; in the
absence of local codes, use the current
CSA C22.1 Canadian Electrical Code.
For USA installations, follow the local
codes and National Electrical Code
ANSI/ NFPA No. 70.
It is strongly suggested the wiring of the
EB-1 Electrical Junction Box be carried
out by a licensed electrician.
Ensure power to the supply line has
been disconnected before commencing
with this procedure.
The EB-1 electrical junction box has been supplied
standard on this model to allow for easy connection of
the optional fan kits (Fig. 6).
To connect the EB-1 box to the house electrical supply
follow the steps below.
1. Remove the front cover of the EB-1 box.
2. Remove the plug socket assembly from the EB-1
box.
3. Feed the supply line in from the out through the
electrical knockout.
4. Connect the ground wire of the supply line to the
green screw of the socket assembly.
5. Connect the white wire of the power line to the
chrome screw of the socket assembly.
6. Connect the black wire of the power supply line to
the brass screw (polarized) of the socket assembly.
7. Refit the socket assembly back into the electrical
box and replace the cover plate.
8. The EB-1 electrical junction box is now ready to
supply power to the FK12 or FK24 fan kit, if used.
EB-1 Electrical Junction Box
Connection
Remote ON/OFF Switch Installation
EB-1_loc
Do not wire the remote ON/OFF wall
switch for this gas appliance into a 120V
power supply.
1. Thread the wiring through the holes on the end
panels of the appliance. Take care not to cut the
wire or insulation on metal edges. Route the wire to
a conveniently located receptacle box.
2. Attach the wire to the ON/OFF switch and install
the switch into the receptacle box.
3. Connect the other ends of the wire to the gas
control valve, as shown in Fig. 7.
Fig. 6 EB-1 attachment
Electrical
Inlet Hole
Gas
Inlet Hole
EB-1 Electrical Box
Depending on the specific model,
this box may be installed on either
side of the appliance.
The gas control is equipped with a captured-screw type
pressure test point, therefore it is not necessary to
provide a
1
/8" test point upstream of the control.
When using copper or flex connector, use only
approved fittings. Always provide a union when using
black iron pipe so that the gas line can be easily
disconnected for burner or fan servicing. See the gas
specification for pressure details and ratings.
Isolate or disconnect this or any other
gas appliance control from the gas line
when pressure testing.
DO NOT subject the fireplace valve to
test pressures exceeding
1
/
2
psi.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 38 39

Comments to this Manuals

No comments