32
Stardance Direct Vent/Natural Vent Gas Heater
20007065
Models 3940, 3950 (RF Models) Only
16. Follow procedure for pilot type 2 to replace pilot
orifice.
17. Remove and replace plug on lower right hand side
of the valve; Red for LP and Blue for NG. (Page 26,
Fig. 49)
18. Remove motor top cap. Depress and turn center
plunger until arrow points to correct screw. Red for
LP and Blue for NG. NOTE: Plunger will “snap” into
NG position when arrow is close to blue screw. It will
not “snap” at LP (Red) position. (Fig. 61)
19. Insure manifold pressure remains between 3.2”
- 3.5” w.c. for NG and 9,5” - 10” w.c. for LP. To adjust
the manifold pressure, for NG, using a torque #10
key turn the blue screw clockwise to increase the
manifold pressure. Turn the screw counterclockwise
to decrease the pressure. Use the red screw to
adjust LP.
20. Replace motor top cap.
All Models
21. Replace burner. Slide the burner in at an angle
with left side lower than the right side. Slide the left
side onto the injectors, making sure the burner leg
remains at a 90° angle to the base. Lower the right
hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.
NOTE: It is very critical to keep the left burner leg,
which holds the injectors, at a 90° angle to the base.
(Fig. 62) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.
22.Place conversion label on valve.
23.Reinstall the right and left log bracket assembly.
24.Reinstall the rear log bracket.
25.Replace logs.
26.Replace glass and stove front.
Conversion is complete.
FP1037b
comfort valve
convert
3/6/01 djt
LOCAL
REMOTE
ON
PILOT
OFF
LED
Motor Top Cap
Center
Plunger
Blue - NG
Red - LP
Valve
FP1037b
Fig. 61 Depress and turn center plunger.
ST353a
injector orifice
replace
3/21/00 djt
90°
Left Burner Leg
Injector Orifice
ST353a
Fig. 62 Remove and replace injector orifices.
Table 2. Injector Orifice Size Matrix
Conversion to Natural Gas Input (Btu/h)
Kit # Front Part # Rear Part # Minimum Maximum
000-5021
#54 / .055” 30000514 #44 / .086” 30000334 19,000 28,000
000-5011
Conversion to LP Input (Btu/h)
Kit # Front Part # Rear Part # Minimum Maximum
000-5022
#69 / .029” 30000513 #54 / .055” 30000514 20,000 28,000
000-5012