7
Radiance
®
Direct Vent Gas Heater
20306759
Parallel Installation:
Minimum Clearance and Flue Centerline
Fig. 3 Parallel installation, minimum back and side clear-
ances, and ue centerlines.
ST130
ST130
alcove specs
10/99
42" (1070mm)
Min. Alcove Width
48"
(1220mm)
Max. Alcove
Depth
6"
(150mm)
6"
(150mm)
4" (102mm)
ST129
ST129
corner specs
10/99
18"
(457mm)
18"
(457mm)
6"
(150mm)
6"
(150mm)
C
L
C
L
Corner Installation:
Minimum Clearance and Flue Centerline
Fig. 4 Corner installation, minimum corner clearances and
ue centerline.
Wall Centerline from Floor
ST131b
Stardance
wall thimble
9/28/00 djt
A
A
Effective Minimum
Centerline 57" (1448 mm)
(Vermont Castings Group Pipe)
55" (1399 mm) (DuraVent Pipe)
ST131b
Fig. 5 Minimum wall centerline.
Direct Vent Only
Hearth Requirements
The Radiance Heater must be installed on rigid ooring.
When the heater is installed directly on any combustible
surface other than wood ooring, a metal or wood panel
extending the full width and depth of the unit must be used
as the hearth. There are no other hearth requirements.
* needed for installing DuraVent Minimum Vent Kit #2792 or
Vermont Castings Group Minimum Vent Kit #7TFSMSK.
A
C
D
ST101b
Stardance
Direct Vent
Min. Clrnc
9/28/00 djt
B
A: Rear Wall 4" (102 mm)
B: Min. Clearance 44" (1118 mm)*
C: Min. Alcove Height 72" (1830 mm)*
D: Max. Alcove Depth 48" (1220 mm)
Sidewall Clearance 6" (150 mm)
ST101b
Fig. 6 Dimensions and clearances to ceiling or alcove.
Direct Vent Only
Wall and Ceiling Clearances