Vermont Castings RADVT(CS)BSSB Operations Instructions Page 38

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 37
3838
Radiance
®
Direct Vent Gas Heater
20306759
Testing Remote Control System
1. Light the gas appliance following the lighting instruc-
tions on Page 32. Conrm the pilot light is on; it must
be in operation for the remote control to operate the
main gas valve and blower. Appliance control knob
must be in the ON position, and ON/OFF switch must
be in OFF position.
2. Slide the 3 position button on the remote receiver to
the ON position and the main gas ame should ignite.
3. Slide the button to OFF and the main gas ame should
extinguish, but the pilot light will remain lit.
4. Slide the button to RS (the center position). Press the
ON button on transmitter to turn the system ON. The
main gas ame should ignite and blower should come
on after the On delay time is reached and fan speed
you desire is selected.
5. Press the OFF button on transmitter to turn the system
to OFF. The ame should extinguish (the pilot light will
remain lit) and blower should be off after the Off delay
time is you set is reached.
Symptom
1. Battery icon on LCD on transmit-
ter.
2. LCD display is blank.
3. LCD display shows “funny" dis-
play.
4. Appliance does not come on.
5. Receiver cannot receive signal.
6. Blower is not on after the stove is
turned on.
Causes
1. Low battery.
1. Wiring/Electrical connections.
2. Privacy (DIP) switch setting on
transmitter does not match re-
ceiver.
3. Transmitter measure tem-
perature exceeding 99°F and
shows “HI" on LCD.
4. Distance between the trans-
mitter and receiver is more
than 30 feet.
1. Receiver is installed in an en-
closure.
1. Blower setting is off.
2. Blower delay setting is set too
high.
Action
1. Replace batteries. Change the bat-
teries every 6 months.
2. Check battery installation or replace
batteries.
3. Press reset button at the back of the
transmitter.
1. Slide the switch to ON, if appliance
comes on, wiring is not the cause.
2. If appliance, does not come on,
check wiring connections.
1. Make sure the transmitter and re-
ceiver have the same DIP switch
settings.
1. Move transmitter to a cooler place
and wait until temperature drops be-
low 99°.
1. Make sure the operating distance is
less than 30 feet.
1. Make sure the receiver is not locat-
ed inside too tight of an enclosure.
1. Press FAN key to select desired fan
speed.
2. Press and hold Fan key to set de-
sired ON/OFF delays. This is done
in minutes.
Troubleshooting
Page view 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 51 52

Comments to this Manuals

No comments